Ultrafloox

Ultra Fast Charging

90-120-150-180-360kw

90-120-150-180-360 kW—DC

Ultra-fast charging stations.

With Ultrafloox’s ultra-fast charging technology, charging electric vehicles has never been faster and more efficient. The Ultrafloox electric charger is capable of providing ultra-fast charging for electric vehicles, which means they can fully charge their batteries in a matter of minutes.

In addition, thanks to its simultaneous charging capacity for two vehicles, the Ultrafloox is perfect for the installation of ultra-fast charging stations on business premises, at electric charging stations, in public places or in HGV transport fleets. If a vehicle is connected, it will have full power available. If another arrives, no queuing is necessary because the power can be split both ways.

This allows electric vehicle drivers to quickly charge their batteries while going about their daily activities, without having to worry about the duration of the charge.
The Ultrafloox ultra-fast charging station is the ideal choice for businesses looking for ultra-fast, efficient and convenient charging for their electric vehicles. Get ready for the future of electric charging with Ultrafloox.

High Power
Simultaneous Charging
User authentication
7 LCD screen
OCPP Compliant
Autocharge
IP55
All-in-one solution

Ideal for

  • Electric charging stations
  • Vehicle dealers
  • Transport fleets
  • Charging point operators

General Specifications

General Specifications

Ultrafloox 90
Ultrafloox 120
Ultrafloox 150
Ultrafloox 180
POWER SPECIFICATIONS
Input voltage
3Φ_380~415Vac (±15%)
AC input connection
3P+N+PE (Wye configuration), TN/TT/IT
Maximum input current
DC system: 3Φ175A AC module (22kw): 3Φ32A (Optional)
Frequency
50Hz/60Hz
Power factor
>0.99
Efficiency
>94%, at optimum V/I point
Output voltage range
CCS2:150~950Vdc CHAdeMO:150~500Vdc AC:3Φ_380~415Vac (Optional)
Maximum output current
CCS2: 250A CHAdeMO:120A@500Vdc AC (22kW):3Φ32A@230Vac (optional)
Maximum output power
DC system:90kW + AC module: 3Φ 22kW (optional)
Voltage accuracy
±2%
Current accuracy
±2%
USER INTERFACE AND CONTROL
Display
TFT-LCD 7″
Button panel
Run button / Emergency stop
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
COMMUNICATION
External
Ethernet, Wi-Fi and 4G
Internal
CAN bus/RS485
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
ENVIRONMENTAL
Operating temperature
-30°C~50°C, power reduced from 50°C
Maximum relative humidity
5%~95% RH, no condensation
Altitude
<2000m
IP/IK level
IP55/IK10
Cooling
Forced ventilation
MECHANICAL
Size
800 x 650 x 1900 mm ±1%
Weight
<395kg ±1%
Hose length
4m
PACKAGING
Gross weight
425kg
Dimensions of wooden box
1180 x 980 x 2090 mm
PROTECTIVE FEATURES
Inlet protective features
OVP, OCP, OPP, OTP, UVP, RCD, SPD
Output protective features
OCP,SCP,OVP, LVP, OTP, OTP, IMD
REGULATION
Certificates
IEC 61851-1, IEC 61851-23, IEC 61851-21-2
Safety
CB, CE
Charging interface
CHAdeMO V1.2, DIN 70121, ISO15118, GB/T 27930
POWER SPECIFICATIONS
Input voltage
3Φ_380~415Vac (±15%)
AC input connection
3P+N+PE (Wye configuration), TN/TT/IT
Maximum input current
DC system: 3Φ230A AC module (22kw): 3Φ32A (Optional)
Frequency
50Hz/60Hz
Power factor
>0.99
Efficiency
>94%, at optimum V/I point
Output voltage range
CCS2:150~950Vdc CHAdeMO:150~500Vdc AC:3Φ_380~415Vac (Optional)
Maximum output current
CCS2: 250A CHAdeMO:120A@500Vdc AC (22kW):3Φ32A@230Vac (optional)
Maximum output power
DC system: 120kW + AC Module: 3Φ 22kW (optional)
Voltage accuracy
±2%
Current accuracy
±2%
USER INTERFACE AND CONTROL
Display
TFT-LCD 7″
Button panel
Run button / Emergency stop
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
COMMUNICATION
External
Ethernet, Wi-Fi and 4G
Internal
CAN bus/RS485
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
ENVIRONMENTAL
Operating temperature
-30°C~50°C, power reduced from 50°C
Maximum relative humidity
5%~95% RH, no condensation
Altitude
<2000m
IP/IK level
IP55/IK10
Cooling
Forced ventilation
MECHANICAL
Size
800 x 650 x 1900 mm ±1%
Weight
<420kg ±1%
Hose length
4m
PACKAGING
Gross weight
450kg
Dimensions wooden box
1180 x 980 x 2090 mm
PROTECTIONS
Inlet protections
OVP, OCP, OPP, OTP, UVP, RCD, SPD
Output protections
OCP,SCP,OVP, LVP, OTP, OTP, IMD
REGULATION
Certificates
IEC 61851-1, IEC 61851-23, IEC 61851-21-2
Safety
CB, CE
Charging interface
CHAdeMO V1.2, DIN 70121, ISO15118, GB/T 27930
POWER SPECIFICATIONS
Input voltage
3Φ_380~415Vac (±15%)
AC input connection
3P+N+PE (Wye configuration), TN/TT/IT
Maximum input current
DC system: 3Φ288A AC module (22kw): 3Φ32A (Optional)
Frequency
50Hz/60Hz
Power factor
>0.99
Efficiency
>94%, at optimum V/I point
Output voltage range
CCS2:150~950Vdc CHAdeMO:150~500Vdc AC:3Φ_380~415Vac (Optional)
Maximum output current
CCS2: 250A CHAdeMO:120A@500Vdc AC (22kW):3Φ32A@230Vac (optional)
Maximum output power
DC system: 150kW + AC Module: 3Φ 22kW (optional)
Voltage accuracy
±2%
Current accuracy
±2%
USER INTERFACE AND CONTROL
Display
TFT-LCD 7″
Button panel
Run button / Emergency stop
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
COMMUNICATION
External
Ethernet, Wi-Fi and 4G
Internal
CAN bus/RS485
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
ENVIRONMENTAL
Operating temperature
-30°C~50°C, power reduced from 50°C
Maximum relative humidity
5%~95% RH, no condensation
Altitude
<2000m
IP/IK level
IP55/IK10
Cooling
Forced ventilation
MECHANICAL
Size
800 x 650 x 1900 mm ±1%
Weight
<445kg ±1%
Hose length
4m
PACKAGING
Gross weight
475kg
Dimensions wooden box
1180 x 980 x 2090 mm
PROTECTIONS
Inlet protections
OVP, OCP, OPP, OTP, UVP, RCD, SPD
Output protections
OCP,SCP,OVP, LVP, OTP, OTP, IMD
REGULATION
Certificates
IEC 61851-1, IEC 61851-23, IEC 61851-21-2
Safety
CB, CE
Charging interface
CHAdeMO V1.2, DIN 70121, ISO15118, GB/T 27930
POWER SPECIFICATIONS
Input voltage
3Φ_380~415Vac (±15%)
AC input connection
3P+N+PE (Wye configuration), TN/TT/IT
Maximum input current
DC system: 3Φ350A AC module (22kw): 3Φ32A (Optional)
Frequency
50Hz/60Hz
Power factor
>0.99
Efficiency
>94%, at optimum V/I point
Output voltage range
CCS2:150~950Vdc CHAdeMO:150~500Vdc AC:3Φ_380~415Vac (Optional)
Maximum output current
CCS2: 250A CHAdeMO:120A@500Vdc AC (22kW):3Φ32A@230Vac (optional)
Maximum output power
DC system: 180kW + AC Module: 3Φ 22kW (optional)
Voltage accuracy
±2%
Current accuracy
±2%
USER INTERFACE AND CONTROL
Display
TFT-LCD 7″
Button panel
Run button / Emergency stop
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
COMMUNICATION
External
Ethernet, Wi-Fi and 4G
Internal
CAN bus/RS485
User authentication
RFID: supports ISO 14443A/B, ISO 15693, FeliCa Lite-S (RCS966) OCPP 1.6 JSON (OCPP 2.0.1 coming soon)
ENVIRONMENTAL
Operating temperature
-30°C~50°C, power reduced from 50°C
Maximum relative humidity
5%~95% RH, no condensation
Altitude
<2000m
IP/IK level
IP55/IK10
Cooling
Forced ventilation
MECHANICAL
Size
800 x 650 x 1900 mm ±1%
Weight
<470kg ±1%
Hose length
4m
PACKAGING
Gross weight
500kg
Dimensions wooden box
1180 x 980 x 2090 mm
PROTECTIONS
Inlet protections
OVP, OCP, OPP, OTP, UVP, RCD, SPD
Output protections
OCP,SCP,OVP, LVP, OTP, OTP, IMD
REGULATION
Certificates
IEC 61851-1, IEC 61851-23, IEC 61851-21-2
Safety
CB, CE
Charging interface
CHAdeMO V1.2, DIN 70121, ISO15118, GB/T 27930

Measurements

Fig 01 / Top
Fig 02
A/ LEFT Side
B/ Front
C/ RIGHT Side
D/ Lateral

Ventilation

Accessories

Cable management system

Dimensions

Charging solutions
Charging solutions
Charging solutions
Charging solutions

Powerfloox

Superfloox

Lyra